This document describes a test to determine the split tensile strength of concrete cylinders. The test involves placing a concrete cylinder between the platens of a compression testing machine and applying a diametric load until the cylinder splits. The maximum load at failure is used to calculate the splitting tensile strength of the concrete according to the formula provided. The test is conducted according to IS 5816-1970 on cylinders that are 15cm in diameter and 30cm in height after a 28 day curing period.