The document discusses cracks in reinforced concrete bridge piers and abutments. It first provides background on the causes of cracking, including applied loads, restraint from volume changes, and drying shrinkage. It then presents a case study of a bridge exhibiting cracks in the abutments and approaches. The cracks are thought to be caused by movement of the abutments due to issues with surrounding soils. The document outlines various remedial measures that could address abutment movement and cracking, such as soil grouting, concrete jacketing, and epoxy injection. It concludes that abutment movement must be addressed to prevent further deterioration of the bridge structure.