This document describes the design and analysis of a residential multi-story building (G+5) using ETABS software. The building is designed using AutoCAD and ETABS to analyze stresses in slabs, beams, columns, floors, walls and footings. Load calculations are performed for dead loads, live loads, lateral loads, axial loads, and seismic or wind loads according to Indian codes. The analysis checks stresses and load capacities of the entire structural system, including reinforcement requirements for columns and staircases. Footings are designed based on soil bearing capacity. The results obtained from analyzing the building structure in ETABS are also discussed.